Filtrine QCP-0.75 Quick Connect Panel

With In-line Filter, Temperature Gauges, Pressure Gauges, Flow Meter

QCP-0.75
A properly operating chiller is essential for the operation of your medical equipment such as MRI, CT or linear accelerator. Filtrine's Model QCP-0.75 quick connect panel provides diagnostic information on your Filtrine medical chiller so that you can see at glance if it is operating correctly and carry out maintenance, if required, to prevent down-time. Filtrine has selected these gauges, etc., in consultation with medical equipment manufacturers, to work with their units.
 
This compact panel is installed between the Filtrine chiller and medical equipment for instantaneous availability of autoswitchover to city water [optional], pressure gauges, temperature gauges, flow meter and in-line filter. The panel is complete with all valves, solenoids, bypass and service drains. An easy-to-open door on the front of the panel provides access to valves and filter for routine maintenance. The complete unit is housed in a enameled aluminum cabinet with stainless steel top, bottom and frame.

Specifications:

Features

Temperature Gauges: For water entering and leaving equipment are dial-type, in Celsius and Fahrenheit, uses probe for maximum accuracy with no pressure drop.

Pressure Gauges: Dial-type, in psi and bar and generate no pressure drop.

Flow Meter: Analog type with moving indicator in liters and gallons per minute, for minimum pressure drop.

Filter: 100 micron pleated filter element in heavy duty stainless steel housing with less than 1 psi pressure drop when new. Filter/housing located inside the panel; includes bypass piping to ensure easy filter element change.

Overall Pressure Drop: Through panel at 10 gpm flow is under 10 psi when filter is clean.

Options

AS – Auto Switchover to City Water: Cooling is already piped for easy access to backup cooling. Power supplied from Filtrine medical chiller is 115/60/1. Switchover occurs on high temperature, low flow and power loss alarms.

HT – High Temperature Interlock: Signals warning light when coolant temperature exceeds high limit. (Located in Filtrine medical chiller.)

LF – Low Flow Interlock: Signals warning light upon loss of coolant flow [pump failure]. (Located in Filtrine medical chiller.)

UPS – Battery Backup: Helps prevent loss of glycol due to nuisance tripping during short power failure, brownout or generator testing.

Connections

Chiller Side: 3/4” FPT [19 mm] copper pipe (other sizes available)
Equipment Side: 3/4” FPT [19 mm]
Service Drain: 1/2” FPT [12.5 mm]

Cabinet

Constructed of enameled aluminum panels with stainless steel top and sides. Panel is removable without tools for access to valves and filter.

Dimensions

30″ [762 mm] W x 10″ [254 mm] D x 36″ [915 mm] H

Weight

Unit Weight: 110 lbs. [50 Kg]

Downloads

Download All

For medical chiller model specification sheets, contact cool@filtrine.com or your local chiller sales representative.