STERI-COOL ® IN-WALL OR IN-COUNTER PURIFIER/CHILLERS

When bottled water is not an option and space is at a premium... specify a Filtrine Steri-Cool ®
These models save considerable floor space while providing pure, chilled "bottled water" piped through the plenum area.
Serve "bottled water" without the bottles... in 4 steps
1. TREAT THE WATER
Filter/Purifier removes
- (A) sediment particles
- (B) chemicals such as chlorine
- (C) organic tastes and odors
- (D) cysts including Cryptosporidium, Giardia, Entamoeba and Toxoplasma.
Optional... Specify LeadMiser™ filter to reduce lead and other heavy metals in the drinking water.
2. CHILL and SAVE ENERGY
Steri-Cool Purifier/Chiller is able to serve constant 45°F temperature water because it employs a large insulated reservoir and energy saving refrigeration unit. This allows the Steri-Cool unit to build a reserve of chilled water during low usage periods to fill personal water containers and handle the peak demands of lunch hours, coffee breaks, etc. and still meet the low average draw. Conventional Electric Water Coolers (EWC's) have none of these features and cycle on and off constantly... wasting energy and shortening the life of the cooler.
3. DISTRIBUTE THROUGH THE PLENUM
The purified chilled water is then distributed through the insulated, flexible piping located in plenum (see schematic) above hung ceiling and drops down as required to feed a random layout of potable water outlets such as break rooms, classrooms or hospital patients' rooms on the same floor. Provide return line for continuous recirculation
4. SERVE "BOTTLED WATER" WITHOUT THE BOTTLES
Bottled water is not the answer to employees who shun conventional tap water bubblers. The logical solution is to install "Filling Stations" - serving pure, chilled water from a Steri-Cool unit - to refill personal water containers or carafes.
Specifying a Steri-Cool Purifier/Chiller eliminates bottle storage, dispensers, disposal and never-ending expense. No more "hand carried" water.
| STERI-COOL IN-WALL or UNDER-COUNTER PURIFIER/CHILLER SELECTION CHART |
STERI
COOL MODEL | REFRIG HP |
PUMP HP |
GAL STORAGE |
NUM
SERVED* |
PIPING |
FILTER PURIFIER MODEL |
UV MODEL |
CHILLER
UNIT DIMS-INCHES | CONTROL
UNIT DIMS - INCHES |
| FT |
IPS |
W |
D |
H |
W |
D |
H |
| ES-2-RF-IW |
1/6 |
NONE |
2 |
50 |
10 |
1/4 |
4TMP-05 |
100S |
24 |
7 |
22 |
40 |
8 |
26 |
| ES-6RFC-IW |
1/4 |
1/25 |
6 |
30 |
100 |
1/2 |
30 |
11 |
25 |
46 |
12 |
31 |
| ES-10-RFC-IW |
1/3 |
1/25 |
10 |
60 |
130 |
1/2 |
30 |
14 |
25 |
46 |
15 |
31 |
|
|