STERI-COOL ® ABOVE-CEILING PURIFIER/CHILLER

Steri-Flo Piping SchematicBetter than Bottled WaterWhen bottled water is not an option and space is at a premium... specify a Filtrine Steri-Cool ® Plenum Mount Purifier/Chiller. These models save considerable floor space while providing pure, chilled "bottled water" piped through the plenum of each floor.

STERI-COOL WATER "ON TAP" ADVANTAGES

  • Designer inspired fountains become a feature in your interior replacing ugly appliances (like EWC's) and water jugs.
  • Save floor space - eliminate bottle storage and dispensers
  • Eliminate bottle disposal problem. Use "filling Stations" to refill personal water containers.
  • Earn LEED credits by specifying a sustainable, energy saving water delivery system

PLENUM PIPING PROVIDES FLEXIBLITY AND ECONOMY

  • One or more Steri-Cool Chiller units is installed in the above-ceiling plenum area.
  • Steri-Cool Control unit is installed in-wall near a wet column, typically in a rest room. It is connected to an insulated flexible piping loop running in the above-ceiling plenum area - like an air conditioning duct - to the Steri-Cool Chiller Unit and from there the line drops down as required to feed a random layout of "filling Stations" or Designer Fountains. Lastly, the water loop returns to the Purifier Unit and the process starts all over again.
  • Chilled, purified drinking water is circulated for all potable water requirements including bubbler, cup fillers, carafe fillers, coffee machines, ice makers... wherever pure water is desired - even in classrooms and patients' rooms in hospitals.

STERI-COOL ABOVE-CEILING PURIFIER/CHILLER SELECTION CHART
STERI
COOL
MODEL
REFRIG
HP
PUMP HP TANK
GAL

PERSONS SERVED§
PIPING FILTER PURIFIER MODEL UV
MODEL
CHILLER
UNIT
INCHES
CHILLER OPT WT - LBS CONTROL
UNIT
INCHES
FT IPS W D H W D H
ES-6-RFC-AC 1/4 1/25 6 180 30 3/8 6TMP-05 100S 23 22 13 150 30 8 30
ES-10-RFC-AC 1/3 1/25 10 200 60 1/2 6TMP-05 100S 25 24 15 200 30 8 30
ES-10-RFC-AC
DUPLEX*
(2)
1/3
(1)
1/25
(2)
10
400 120 1/2 10TMP-05 200S (2)
25
(2) 24 (2) 15 (2)
200
30 8 44
ES-10-RFC-AC
TRIPLEX**
(3)
1/3
(1)
1/5
(3)
10
600 180 1/2 10TMP-05-DUPLEX 200S (3)
25
(3) 24 (3) 15 (3)
200
40 8 44
ES-10-RFC-AC
QUADRUPLEX***
(4)
1/3
(4)
1/25
(4)
10
800 240 1/2 10TMP-05-TRIPLEX 200S (4)
25
(4) 24 (4) 25 (4)
200
50 8 44

§ Assume 1 qt. (09L) per day per person in typical usage. Capacities based on 80°'F (27°C) inlet, 50°F (7°C) outlet. ES models include extra capacity to handle heat loss of insulated piping in the circulating loop up to the length shown. When piping runs exceed allowance shown, reduce population served by 50 people per 50 feet of additional piping.
* (1) Control Unit & (2) Chiller units
** (1) Control Unit & (3) Chiller Units
*** (1) Control Unit & (4) Chiller Units